Skip to content

300,000+ products in stockAI infrastructure + enterprise IT hardware. Genuine product, full manufacturer warranty.

VP4UV0A2 — Vertiv Geist Universal Rack PDU with Next-Generation IMD, 32A-63A, 22kW, 208V-415V, (30) Combination Outlets

MPN: VP4UV0A2|By: Vertiv

Vertiv Geist Universal Rack PDU with Next-Generation IMD, 32A-63A, 22kW, 208V-415V, (30) Combination Outlets

In Stockships worldwide

Condition:
New — authorized channel
Warranty:
Full manufacturer warranty

Get pricing and availability

Email + WhatsApp so we always reach you.

Prefer your own inbox? Email us about this part

Have questions?

Talk to a hardware specialist.

WhatsAppEmail

Bulk order? Request volume pricing

Product overview

This is the Vertiv geist universal rack PDU with next-generation IMD, 32A-63A, 22kW, 208V-415V, (30) combination outlets, order code VP4UV0A2. Network management cards, environmental probes and the shutdown software are usually what make a UPS useful, and they are ordered separately. This unit is 208V. Tell us the monitoring you need and we will quote it as one bill of materials.

Quotes are itemised down to the accessories, so nothing that is needed to make the part work is left off and discovered later.

Featuring

Power Capacity
22kW
Current Rating
32A
Manufacturer
Vertiv

Physical characteristics

Product Type
Power Distribution & UPS

Miscellaneous

Input Voltage
208V
  • Expedited shipping options are available — rates confirmed with your quote.
  • Purchase orders accepted from qualified institutions.
  • Compatibility is validated against your server platform before dispatch. Send us the model and we will confirm support.

The table below is what the PDU is documented as, not what we have inferred from the part number. If the figure you need is missing, ask and we will source it from the manufacturer.

Where the Vertiv VP4UV0A2 is deployed

  • Sourcing VP4UV0A2 against a build sheet that names it explicitly
  • Replacing batteries or a UPS at end of service life
  • Adding metered or switched power to an existing cabinet

Who this part is for

  • Teams replacing batteries or a UPS at end of service life
  • Data centre teams matching outlet type and phase to a rack build
  • Procurement buying power hardware ahead of a scheduled install

What you get ordering this from us

Ordered by part number

VP4UV0A2 is what is quoted and VP4UV0A2 is what ships; where an alternate code is genuinely the same part we name it rather than swap it silently.

Sized on measured load

Runtime is calculated from what the rack actually draws rather than from nameplate wattage.

Answered by a human

A quote comes back with the reasoning attached, including the cases where we think you should buy something else.

Questions buyers ask about this part

Is VP4UV0A2 genuine and is the warranty intact?
Yes. Supplied new and unopened, so the manufacturer warranty and firmware update path stay supported. No grey-market stock and no refurbished units sold as new.
Will VP4UV0A2 work in my server?
Tell us the circuit feeding the rack, the plug types in it and the measured load. Outlet count is the last thing that matters; phase, connector and real draw are the first three.
Do you accept purchase orders and quote at volume?
Yes — POs from qualified organisations, net terms on approval, and banded pricing once the quantity is worth banding. Send the number and we will price it properly.

Compare other Power Distribution & UPS we stock

Browse all Power Distribution & UPS or everything we stock from Vertiv.

Specifying a system, not just the part?

Most parts we ship go into a system we also build and support.