SURT8000XLT-1TF3: APC Smart-UPS RT 8000VA 208V w/ 208V to 120V Step-Down Transformer
MPN: SURT8000XLT-1TF3|By: APC

Starting from
$5,420
Indicative. Final pricing is confirmed with your quote.
In Stockships worldwide
Key specs
- Input Voltage
- 110 V AC; 220 V AC
- Product Model
- SURT8000XLT-1TF3
- Form Factor
- Tower
- Load Capacity (VA)
- 8000 VA
- Output Voltage
- 120 V AC; 208 V AC
- Condition:
- New (authorized channel)
- Warranty:
- Manufacturer warranty, confirmed on your quote
Prefer your own inbox? Email us about this part
Bulk order? Request volume pricing
Authorized & warrantied
Sourced through authorized distribution, with the manufacturer warranty confirmed on your quote.
Compatibility checked
Validated against your server platform before dispatch.
Delivery & lead time
Confirmed with your quote, including expedited freight where available.
Business & public sector
POs, net terms and volume pricing for qualified organizations, government and edu.
Product overview
Part number SURT8000XLT-1TF3 identifies this APC Smart-UPS RT 8000VA 208V w/ 208V to 120V step-down transformer. A PDU is chosen on outlet type, phase and the circuit feeding the rack, not on outlet count. Tell us the supply and the plug types in the rack and we will confirm the model.
APC publishes SURT8000XLT-1TF3 with a 110 V AC; 220 V AC input, a tower form factor, an 8000 VA load rating and 6.30 minutes of run time at full load.
Ask for the datasheet and firmware notes with the quote; we would rather you check our claim than take it.
Specifications
General
- Manufacturer part number
- SURT8000XLT-1TF3
- Product Line
- Smart-UPS
- Product Type
- Power Distribution & UPS
- Manufacturer
- APC
Technical specifications
- Input Voltage
- 110 V AC; 220 V AC
- Product Model
- SURT8000XLT-1TF3
- Load Capacity (VA)
- 8000 VA
- Output Voltage
- 120 V AC; 208 V AC
- Run Time (Full Load)
- 6.30 Minute
- Run Time (Half Load)
- 17.90 Minute
- Receptacle Type
- Hard Wire 3-wire; NEMA 5-20R; NEMA L14-30R; NEMA L6-20R; NEMA L6-30R
- Input Frequency
- 60 Hz
- Network Management
- SNMP Manageable
- Bypass Switch
- Automatic & Manual
- Battery Characteristics
- Spill-proof/Maintenance-free
- Battery Chemistry
- Lead Acid
- Typical Battery Recharge Time
- 2.20 Hour
- Software Included
- PowerChute Software
Interfaces & connectivity
- Plug/Connector Type
- Hard Wire 3-wire
- Modular Slots
- SmartSlot
Physical
- Form Factor
- Tower
Everything below comes from APC's published specification for this PDU, covering input voltage, form factor, load capacity (VA) and output voltage. If you need a figure that is not listed, ask and we will source it.
Where the APC SURT8000XLT-1TF3 is deployed
- Like-for-like replacement of SURT8000XLT-1TF3 in an existing system
- Matching outlet type and phase to a new rack build
- Adding metered or switched power to an existing cabinet
Who this part is for
- Integrators quoting PDUs, management cards and probes together
- Procurement buying power hardware ahead of a scheduled install
- Data centre teams matching outlet type and phase to a rack build
What you get ordering this from us
Ordered by part number
The order is placed against SURT8000XLT-1TF3, not against a description of it, so there is no room for a substitution you did not agree to.
Volume pricing
The listed price is per unit; tiered pricing applies at quantity and purchase orders are accepted.
No substitutions without asking
If we cannot supply the exact code we tell you what we can supply and why, rather than shipping an equivalent and letting you find out.
Questions buyers ask about this part
Is SURT8000XLT-1TF3 genuine and is the warranty intact?
Yes. It ships new in APC packaging, which is what keeps the warranty and the firmware entitlement valid. Anything we cannot supply that way we tell you about before you order.
Will SURT8000XLT-1TF3 work in my server?
Tell us the circuit feeding the rack, the plug types in it and the measured load. Outlet count is the last thing that matters; phase, connector and real draw are the first three.
What load is SURT8000XLT-1TF3 rated for?
APC rates SURT8000XLT-1TF3 at 8000 VA, with a run time of 6.30 minutes at full load. Size it against the measured draw of what it protects, not the nameplate total.
What form factor is SURT8000XLT-1TF3?
SURT8000XLT-1TF3 uses the tower form factor.
What should I check before ordering SURT8000XLT-1TF3?
Check that 8000 VA covers your measured load with headroom, that the supply is 110 V AC; 220 V AC and that your outlet takes a Hard Wire 3-wire plug. Send us the model it is going into and we will confirm all three before APC SURT8000XLT-1TF3 ships.
Do you accept purchase orders and quote at volume?
Yes, POs from qualified organisations, net terms on approval, and banded pricing once the quantity is worth banding. Send the number and we will price it properly.
Compare other Power Distribution & UPS we stock
| Model | Brand | Key spec | Availability | From |
|---|---|---|---|---|
| Vertiv Geist GU10012L Metered 0U 24-Outlet | Vertiv | Capacity: 7.4kW | In Stock | $1,405 |
| Tripp Lite PDUMH15 Metered 1U 8-Outlet | Tripp Lite | Capacity: 1.4kW | In Stock | $310 |
| Eaton 5PX 1500VA 2U Rack/Tower | Eaton | Capacity: 1350W / 1500VA | In Stock | $1,065 |
| Nexus Compute C13 to C14 Power Cable 0.5m | Nexus Compute | Capacity: 10A 250V | In Stock | $5 |
| Dell Power Distribution Board Cable | Dell | N/A | In Stock | Request quote |
| Vertiv (Liebert) Liebert 4500W (5kVA) 120/208V Hot-Swap Power Module for Liebert APS AS5/AS6 UPS Systems | Vertiv (Liebert) | Power Rating: 4500W | In Stock | $4,585 |
Browse all Power Distribution & UPS or everything we stock from APC.
Specifying a system, not just the part?
Most parts we ship go into a system we also build and support.