PWATSL630008: Eaton ePDU 1-Outlet 4.99kVA PDU
MPN: PWATSL630008|By: Eaton

Starting from
$1,495
Indicative. Final pricing is confirmed with your quote.
In Stockships worldwide
Key specs
- Input Voltage
- 230 V AC
- Apparent Power
- 99kVA
- Output Voltage
- 240 V AC
- Rack Height
- 1U
- Plug/Connector Type
- NEMA L6-30P
- Condition:
- New (authorized channel)
- Warranty:
- Manufacturer warranty, confirmed on your quote
Prefer your own inbox? Email us about this part
Bulk order? Request volume pricing
Authorized & warrantied
Sourced through authorized distribution, with the manufacturer warranty confirmed on your quote.
Compatibility checked
Validated against your server platform before dispatch.
Delivery & lead time
Confirmed with your quote, including expedited freight where available.
Business & public sector
POs, net terms and volume pricing for qualified organizations, government and edu.
Product overview
PWATSL630008 is an Eaton ePDU 1-Outlet 4.99kVA PDU. Runtime is a function of load, and a UPS sized on nameplate wattage rather than measured draw will not hold the rack for as long as the datasheet suggests. This unit is 99kVA. Tell us the measured load and we will work the runtime out properly.
PWATSL630008 is specified with a 230 V AC input and a rack height of 1U, as published by Eaton.
If the part is wrong for your platform we will say so and suggest the one that is, which is cheaper for both of us than a return.
Specifications
General
- Manufacturer part number
- PWATSL630008
- Product Line
- ePDU
- Product Type
- Power Distribution & UPS
- Manufacturer
- Eaton
Technical specifications
- Apparent Power
- 99kVA
- Input Voltage
- 230 V AC
- Output Voltage
- 240 V AC
- Receptacle Type
- NEMA L6-30R
- Receptacle Detail
- 1 x NEMA L6-30R
- Protection Type
- Spike Protection; Surge Protection
- Power Rating (VA)
- 4990 VA
- Mount Type
- Rack-mountable
- Width
- 19"
Interfaces & connectivity
- Plug/Connector Type
- NEMA L6-30P
Physical
- Rack Height
- 1U
- Height
- 1.7"
- Depth
- 7"
- Weight
- 19 lb
Everything below comes from Eaton's published specification for this PDU, covering apparent power, input voltage, output voltage and rack height. If you need a figure that is not listed, ask and we will source it.
Where the Eaton PWATSL630008 is deployed
- Sourcing PWATSL630008 against a build sheet that names it explicitly
- Replacing batteries or a UPS at end of service life
- Adding metered or switched power to an existing cabinet
Who this part is for
- Facilities and IT sizing runtime against measured rather than nameplate load
- Data centre teams matching outlet type and phase to a rack build
- Integrators quoting PDUs, management cards and probes together
What you get ordering this from us
Ordered by part number
PWATSL630008 is what is quoted and PWATSL630008 is what ships; where an alternate code is genuinely the same part we name it rather than swap it silently.
Compatibility checked
We confirm the part is supported on your platform before it ships, rather than leaving the check to you.
Sized on measured load
Runtime is calculated from what the rack actually draws rather than from nameplate wattage.
Questions buyers ask about this part
Is PWATSL630008 genuine and is the warranty intact?
Yes. It ships new in Eaton packaging, which is what keeps the warranty and the firmware entitlement valid. Anything we cannot supply that way we tell you about before you order.
Will PWATSL630008 work in my server?
Tell us the circuit feeding the rack, the plug types in it and the measured load. Outlet count is the last thing that matters; phase, connector and real draw are the first three.
What form factor is PWATSL630008?
PWATSL630008 is rack mounted, takes 1U of rack space.
What are the dimensions and weight of PWATSL630008?
PWATSL630008 measures 1.7" high, 19" wide and 7" deep, and weighs about 19 lb.
What should I check before ordering PWATSL630008?
Check that the supply is 230 V AC and that your outlet takes a NEMA L6-30P plug. Send us the model it is going into and we will confirm both before Eaton PWATSL630008 ships.
Do you accept purchase orders and quote at volume?
Yes. Purchase orders are accepted from qualified organisations, net terms are available on approval, and tiered pricing applies at quantity. Tell us how many you need.
Compare other Power Distribution & UPS we stock
| Model | Brand | Key spec | Availability | From |
|---|---|---|---|---|
| APC AP7921B Switched Rack PDU 8-Outlet 1U | APC | Capacity: 3.7kW | In Stock | $805 |
| Vertiv Geist GU10012L Metered 0U 24-Outlet | Vertiv | Capacity: 7.4kW | In Stock | $1,405 |
| Tripp Lite PDUMH15 Metered 1U 8-Outlet | Tripp Lite | Capacity: 1.4kW | In Stock | $310 |
| Nexus Compute C13 to C14 Power Cable 0.5m | Nexus Compute | Capacity: 10A 250V | In Stock | $5 |
| Dell Power Distribution Board Cable | Dell | N/A | In Stock | Request quote |
| Vertiv (Liebert) Liebert 4500W (5kVA) 120/208V Hot-Swap Power Module for Liebert APS AS5/AS6 UPS Systems | Vertiv (Liebert) | Power Rating: 4500W | In Stock | $4,585 |
Browse all Power Distribution & UPS or everything we stock from Eaton.
Specifying a system, not just the part?
Most parts we ship go into a system we also build and support.