PS1500RT3120XRW: Vertiv Liebert PSI 1500VA Line-Interactive Rack/Tower UPS
MPN: PS1500RT3120XRW|By: Vertiv

Price
Quoted on request
Current pricing within 48 business hours.
In Stockships worldwide
Key specs
- UPS Topology
- Line-Interactive
- Input Voltage
- 120 V AC
- Product Model
- PSI
- Form Factor
- Rack/Tower
- Load Capacity (VA)
- 1500 VA
- Condition:
- New (authorized channel)
- Warranty:
- Manufacturer warranty, confirmed on your quote
Prefer your own inbox? Email us about this part
Bulk order? Request volume pricing
Authorized & warrantied
Sourced through authorized distribution, with the manufacturer warranty confirmed on your quote.
Compatibility checked
Validated against your server platform before dispatch.
Delivery & lead time
Confirmed with your quote, including expedited freight where available.
Business & public sector
POs, net terms and volume pricing for qualified organizations, government and edu.
Product overview
Vertiv lists PS1500RT3120XRW as a liebert PSI 1500VA line-interactive rack/tower UPS. Runtime is a function of load, and a UPS sized on nameplate wattage rather than measured draw will not hold the rack for as long as the datasheet suggests. Tell us the measured load and we will work the runtime out properly.
PS1500RT3120XRW is specified with Line-Interactive topology, a Rack/Tower form factor, a 1500 VA load rating, a 120 V AC input and 5 minutes of run time at full load, as published by Vertiv.
Quote requests are answered within 48 business hours, with availability confirmed before you raise a purchase order rather than after.
Specifications
General
- Manufacturer part number
- PS1500RT3120XRW
- Product Type
- Power Distribution & UPS
- Manufacturer
- Vertiv
Technical specifications
- UPS Topology
- Line-Interactive
- Product Model
- PSI
- Load Capacity (VA)
- 1500 VA
- Load Capacity (W)
- 1350 W
- Input Voltage
- 120 V AC
- Output Voltage
- 159 V AC
- Run Time (Full Load)
- 5 Minute
- Run Time (Half Load)
- 10 Minute
- Waveform Type
- Pure Sine Wave
- Receptacle Type
- NEMA 5-15R
- Receptacle Detail
- 6 x NEMA 5-15R
- Protection Type
- Lightning; Surge; Noise
- Cord Length
- 10 ft
- Transfer Time
- 6 ms
- Phase
- Single Phase
- Input Voltage Range
- 83 V AC - 159 V AC
Interfaces & connectivity
- Plug/Connector Type
- NEMA 5-15P
Physical
- Form Factor
- Rack/Tower
- Rack Height
- 2U
The table lists 21 published specifications for PS1500RT3120XRW, including UPS topology, form factor, load capacity (VA) and load capacity (W). Values are as Vertiv publishes them; ask and we will send the datasheet with the quote.
Where the Vertiv PS1500RT3120XRW is deployed
- Like-for-like replacement of PS1500RT3120XRW in an existing system
- Replacing batteries or a UPS at end of service life
- Sizing runtime for a scheduled maintenance window
Who this part is for
- Facilities and IT sizing runtime against measured rather than nameplate load
- Data centre teams matching outlet type and phase to a rack build
- Teams replacing batteries or a UPS at end of service life
What you get ordering this from us
Ordered by part number
PS1500RT3120XRW is what is quoted and PS1500RT3120XRW is what ships; where an alternate code is genuinely the same part we name it rather than swap it silently.
Compatibility checked
We confirm the part is supported on your platform before it ships, rather than leaving the check to you.
Answered by a human
A quote comes back with the reasoning attached, including the cases where we think you should buy something else.
Questions buyers ask about this part
Is PS1500RT3120XRW genuine and is the warranty intact?
Yes, new and sealed, with the Vertiv warranty and the firmware update path intact. We do not sell refurbished stock as new, and we do not source grey-market units.
Will PS1500RT3120XRW work in my server?
Tell us the circuit feeding the rack, the plug types in it and the measured load. Outlet count is the last thing that matters; phase, connector and real draw are the first three.
What is the power rating of PS1500RT3120XRW?
Vertiv rates PS1500RT3120XRW at 1500 VA / 1350 W, with pure sine wave output, with a run time of 5 minutes at full load. Size it against the measured draw of what it protects, not the nameplate total.
What form factor is PS1500RT3120XRW?
PS1500RT3120XRW uses the Rack/Tower form factor and takes 2U of rack space.
What should I check before ordering PS1500RT3120XRW?
Check that 1500 VA covers your measured load with headroom, that the supply is 120 V AC and that your outlet takes a NEMA 5-15P plug. Send us the model it is going into and we will confirm all three before Vertiv PS1500RT3120XRW ships.
Do you accept purchase orders and quote at volume?
Yes, POs from qualified organisations, net terms on approval, and banded pricing once the quantity is worth banding. Send the number and we will price it properly.
Compare other Power Distribution & UPS we stock
| Model | Brand | Key spec | Availability | From |
|---|---|---|---|---|
| APC AP7921B Switched Rack PDU 8-Outlet 1U | APC | Capacity: 3.7kW | In Stock | $805 |
| Tripp Lite PDUMH15 Metered 1U 8-Outlet | Tripp Lite | Capacity: 1.4kW | In Stock | $310 |
| Eaton 5PX 1500VA 2U Rack/Tower | Eaton | Capacity: 1350W / 1500VA | In Stock | $1,065 |
| Nexus Compute C13 to C14 Power Cable 0.5m | Nexus Compute | Capacity: 10A 250V | In Stock | $5 |
| Dell Power Distribution Board Cable | Dell | N/A | In Stock | Request quote |
| Vertiv (Liebert) Liebert 4500W (5kVA) 120/208V Hot-Swap Power Module for Liebert APS AS5/AS6 UPS Systems | Vertiv (Liebert) | Power Rating: 4500W | In Stock | $4,585 |
Browse all Power Distribution & UPS or everything we stock from Vertiv.
Specifying a system, not just the part?
Most parts we ship go into a system we also build and support.