PR2200RTXL2U: CyberPower Smart App Sinewave UPS Systems
MPN: PR2200RTXL2U|By: CyberPower

Starting from
$1,110
Indicative. Final pricing is confirmed with your quote.
In Stockships worldwide
Key specs
- Input Voltage
- 120 V AC
- Form Factor
- Rack/Tower
- Load Capacity (VA)
- 2200 VA
- Run Time (Full Load)
- 3.20 Minute
- Run Time (Half Load)
- 10 Minute
- Condition:
- New (authorized channel)
- Warranty:
- Manufacturer warranty, confirmed on your quote
Prefer your own inbox? Email us about this part
Bulk order? Request volume pricing
Authorized & warrantied
Sourced through authorized distribution, with the manufacturer warranty confirmed on your quote.
Compatibility checked
Validated against your server platform before dispatch.
Delivery & lead time
Confirmed with your quote, including expedited freight where available.
Business & public sector
POs, net terms and volume pricing for qualified organizations, government and edu.
Product overview
Part number PR2200RTXL2U identifies this CyberPower smart app sinewave UPS systems. Batteries are consumable and are the part most likely to be out of date on arrival. We confirm the manufacture date before dispatch and quote replacement packs alongside.
The headline figures for this PDU: a Rack/Tower form factor, a 2200 VA load rating, a 120 V AC input, 3.20 minutes of run time at full load and a rack height of 2U.
Tell us the deadline you are working to and we will say whether it is achievable before you commit to it internally.
Specifications
General
- Manufacturer part number
- PR2200RTXL2U
- Product Type
- Power Distribution & UPS
- Manufacturer
- CyberPower
Technical specifications
- Load Capacity (VA)
- 2200 VA
- Input Voltage
- 120 V AC
- Output Voltage
- 100 V AC; 110 V AC; 120 V AC
- Run Time (Full Load)
- 3.20 Minute
- Run Time (Half Load)
- 10 Minute
- Waveform Type
- Sine Wave
- AVR Range
- Boost +2% / Buck -1%
- Receptacle Type
- NEMA 5-20R
- Receptacle Detail
- 8 x NEMA 5-20R
- Number of Battery & Surge Outlets
- 8
- Number of Critical Load Outlets
- 4
- Transfer Time
- 4 ms
- Dataline Protection
- RJ-45
- Energy Saving
- GreenPower UPS™ Bypass Technology
- Input Voltage Range
- 75 V AC - 155 V AC
Interfaces & connectivity
- Plug/Connector Type
- NEMA L5-30P
Physical
- Form Factor
- Rack/Tower
- Rack Height
- 2U
Everything below comes from CyberPower's published specification for this PDU, covering form factor, load capacity (VA), input voltage and output voltage. If you need a figure that is not listed, ask and we will source it.
Where the CyberPower PR2200RTXL2U is deployed
- Like-for-like replacement of PR2200RTXL2U in an existing system
- Matching outlet type and phase to a new rack build
- Adding metered or switched power to an existing cabinet
Who this part is for
- Integrators quoting PDUs, management cards and probes together
- Procurement buying power hardware ahead of a scheduled install
- Data centre teams matching outlet type and phase to a rack build
What you get ordering this from us
Ordered by part number
Quoted and supplied against PR2200RTXL2U specifically, so what arrives is what your build sheet asks for.
No substitutions without asking
If we cannot supply the exact code we tell you what we can supply and why, rather than shipping an equivalent and letting you find out.
Sized on measured load
Runtime is calculated from what the rack actually draws rather than from nameplate wattage.
Questions buyers ask about this part
Is PR2200RTXL2U genuine and is the warranty intact?
Yes. It ships new in CyberPower packaging, which is what keeps the warranty and the firmware entitlement valid. Anything we cannot supply that way we tell you about before you order.
Will PR2200RTXL2U work in my server?
Tell us the circuit feeding the rack, the plug types in it and the measured load. Outlet count is the last thing that matters; phase, connector and real draw are the first three.
What load is PR2200RTXL2U rated for?
CyberPower rates PR2200RTXL2U at 2200 VA, with sine wave output, with a run time of 3.20 minutes at full load. Size it against the measured draw of what it protects, not the nameplate total.
What form factor is PR2200RTXL2U?
PR2200RTXL2U uses the Rack/Tower form factor and takes 2U of rack space.
What should I check before ordering PR2200RTXL2U?
Check that 2200 VA covers your measured load with headroom, that the supply is 120 V AC and that your outlet takes a NEMA L5-30P plug. Send us the model it is going into and we will confirm all three before CyberPower PR2200RTXL2U ships.
Do you accept purchase orders and quote at volume?
Yes, POs from qualified organisations, net terms on approval, and banded pricing once the quantity is worth banding. Send the number and we will price it properly.
Compare other Power Distribution & UPS we stock
| Model | Brand | Key spec | Availability | From |
|---|---|---|---|---|
| APC AP7921B Switched Rack PDU 8-Outlet 1U | APC | Capacity: 3.7kW | In Stock | $805 |
| Vertiv Geist GU10012L Metered 0U 24-Outlet | Vertiv | Capacity: 7.4kW | In Stock | $1,405 |
| Tripp Lite PDUMH15 Metered 1U 8-Outlet | Tripp Lite | Capacity: 1.4kW | In Stock | $310 |
| Eaton 5PX 1500VA 2U Rack/Tower | Eaton | Capacity: 1350W / 1500VA | In Stock | $1,065 |
| Nexus Compute C13 to C14 Power Cable 0.5m | Nexus Compute | Capacity: 10A 250V | In Stock | $5 |
| Dell Power Distribution Board Cable | Dell | N/A | In Stock | Request quote |
Browse all Power Distribution & UPS or everything we stock from CyberPower.