PR2200LCD: CyberPower Smart App Sinewave UPS Systems
MPN: PR2200LCD|By: CyberPower

Starting from
$1,285
Indicative. Final pricing is confirmed with your quote.
In Stockships worldwide
Key specs
- Input Voltage
- 120 V AC
- Product Model
- PR2200LCD
- Form Factor
- Tower
- Load Capacity (VA)
- 2200 VA
- Load Capacity (W)
- 1980 W
- Condition:
- New (authorized channel)
- Warranty:
- Manufacturer warranty, confirmed on your quote
Prefer your own inbox? Email us about this part
Bulk order? Request volume pricing
Authorized & warrantied
Sourced through authorized distribution, with the manufacturer warranty confirmed on your quote.
Compatibility checked
Validated against your server platform before dispatch.
Delivery & lead time
Confirmed with your quote, including expedited freight where available.
Business & public sector
POs, net terms and volume pricing for qualified organizations, government and edu.
Product overview
Part number PR2200LCD identifies this CyberPower smart app sinewave UPS systems. A PDU is chosen on outlet type, phase and the circuit feeding the rack, not on outlet count. Tell us the supply and the plug types in the rack and we will confirm the model.
CyberPower publishes PR2200LCD with a tower form factor, a 2200 VA load rating, a 120 V AC input, 8 minutes of run time at full load and a 10 ft cord.
Ask for the datasheet and firmware notes with the quote; we would rather you check our claim than take it.
Specifications
General
- Manufacturer part number
- PR2200LCD
- Product Type
- Power Distribution & UPS
- Manufacturer
- CyberPower
Technical specifications
- Product Model
- PR2200LCD
- Load Capacity (VA)
- 2200 VA
- Load Capacity (W)
- 1980 W
- Input Voltage
- 120 V AC
- Run Time (Full Load)
- 8 Minute
- Run Time (Half Load)
- 26 Minute
- Waveform Type
- Sine Wave
- Receptacle Type
- NEMA 5-15R
- Receptacle Detail
- 8 x NEMA 5-15R
- Number of Battery & Surge Outlets
- 10
- Transfer Time
- 4 ms
- Energy Saving
- GreenPower UPS™ Bypass Technology
- Cord Length
- 10 ft
- Circuit Breaker Current Rating
- 30 A
- Input Voltage Range
- 75 V AC - 154 V AC
- Input Frequency
- 50 Hz; 60 Hz
Interfaces & connectivity
- Plug/Connector Type
- NEMA L5-30P
Physical
- Form Factor
- Tower
Everything below comes from CyberPower's published specification for this PDU, covering form factor, load capacity (VA), load capacity (W) and input voltage. If you need a figure that is not listed, ask and we will source it.
Where the CyberPower PR2200LCD is deployed
- Swapping out a failed PDU for PR2200LCD under change control
- Adding metered or switched power to an existing cabinet
- Replacing batteries or a UPS at end of service life
Who this part is for
- Procurement buying power hardware ahead of a scheduled install
- Facilities and IT sizing runtime against measured rather than nameplate load
- Data centre teams matching outlet type and phase to a rack build
What you get ordering this from us
Ordered by part number
PR2200LCD is what is quoted and PR2200LCD is what ships; where an alternate code is genuinely the same part we name it rather than swap it silently.
No substitutions without asking
If we cannot supply the exact code we tell you what we can supply and why, rather than shipping an equivalent and letting you find out.
Compatibility checked
We confirm the part is supported on your platform before it ships, rather than leaving the check to you.
Questions buyers ask about this part
Is PR2200LCD genuine and is the warranty intact?
Yes. It ships new in CyberPower packaging, which is what keeps the warranty and the firmware entitlement valid. Anything we cannot supply that way we tell you about before you order.
Will PR2200LCD work in my server?
Tell us the circuit feeding the rack, the plug types in it and the measured load. Outlet count is the last thing that matters; phase, connector and real draw are the first three.
What load is PR2200LCD rated for?
CyberPower rates PR2200LCD at 2200 VA / 1980 W, with sine wave output, with a run time of 8 minutes at full load. Size it against the measured draw of what it protects, not the nameplate total.
What form factor is PR2200LCD?
PR2200LCD uses the tower form factor.
What should I check before ordering PR2200LCD?
Check that 2200 VA covers your measured load with headroom, that the supply is 120 V AC and that your outlet takes a NEMA L5-30P plug. Send us the model it is going into and we will confirm all three before CyberPower PR2200LCD ships.
Do you accept purchase orders and quote at volume?
Yes. We quote against a purchase order and hold the price for the quote period, with tiered rates at quantity. Net terms are available once the account is approved.
Compare other Power Distribution & UPS we stock
| Model | Brand | Key spec | Availability | From |
|---|---|---|---|---|
| APC AP7921B Switched Rack PDU 8-Outlet 1U | APC | Capacity: 3.7kW | In Stock | $805 |
| Vertiv Geist GU10012L Metered 0U 24-Outlet | Vertiv | Capacity: 7.4kW | In Stock | $1,405 |
| Tripp Lite PDUMH15 Metered 1U 8-Outlet | Tripp Lite | Capacity: 1.4kW | In Stock | $310 |
| Eaton 5PX 1500VA 2U Rack/Tower | Eaton | Capacity: 1350W / 1500VA | In Stock | $1,065 |
| Nexus Compute C13 to C14 Power Cable 0.5m | Nexus Compute | Capacity: 10A 250V | In Stock | $5 |
| Dell Power Distribution Board Cable | Dell | N/A | In Stock | Request quote |
Browse all Power Distribution & UPS or everything we stock from CyberPower.
Specifying a system, not just the part?
Most parts we ship go into a system we also build and support.