PR2000RTXL2UTAA: CyberPower TAA Compliant UPS Systems
MPN: PR2000RTXL2UTAA|By: CyberPower

Starting from
$1,305
Indicative. Final pricing is confirmed with your quote.
In Stockships worldwide
Key specs
- Input Voltage
- 120 V AC
- Compliance
- TAA
- Form Factor
- Rack/Tower
- Load Capacity (VA)
- 2000 VA
- Run Time (Full Load)
- 4.30 Minute
- Condition:
- New (authorized channel)
- Warranty:
- Manufacturer warranty, confirmed on your quote
Prefer your own inbox? Email us about this part
Bulk order? Request volume pricing
Authorized & warrantied
Sourced through authorized distribution, with the manufacturer warranty confirmed on your quote.
Compatibility checked
Validated against your server platform before dispatch.
Delivery & lead time
Confirmed with your quote, including expedited freight where available.
Business & public sector
POs, net terms and volume pricing for qualified organizations, government and edu.
Product overview
Part number PR2000RTXL2UTAA identifies this CyberPower TAA compliant UPS systems. Batteries are consumable and are the part most likely to be out of date on arrival. We confirm the manufacture date before dispatch and quote replacement packs alongside.
The headline figures for this PDU: a Rack/Tower form factor, a 2000 VA load rating, a 120 V AC input, 4.30 minutes of run time at full load and a rack height of 2U.
Tell us the deadline you are working to and we will say whether it is achievable before you commit to it internally.
Specifications
General
- Manufacturer part number
- PR2000RTXL2UTAA
- Product Type
- Power Distribution & UPS
- Manufacturer
- CyberPower
Technical specifications
- Product Model
- PR2000RTXL2UTAA
- Load Capacity (VA)
- 2000 VA
- Input Voltage
- 120 V AC
- Output Voltage
- 110 V AC; 120 V AC; 125 V AC; 100 V AC
- Run Time (Full Load)
- 4.30 Minute
- Run Time (Half Load)
- 12.20 Minute
- Waveform Type
- Sine Wave
- TAA Compliant
- Yes
- Receptacle Type
- NEMA 5-20R
- Receptacle Detail
- 8 x NEMA 5-20R
- Number of Battery & Surge Outlets
- 8
- Number of Critical Load Outlets
- 4
- Transfer Time
- 4 ms
- Dataline Protection
- RJ-45
- Energy Saving
- GreenPower UPS™ Bypass Technology
Interfaces & connectivity
- Plug/Connector Type
- NEMA 5-20P
Physical
- Form Factor
- Rack/Tower
- Rack Height
- 2U
Compatibility & compliance
- Compliance
- TAA
Everything below comes from CyberPower's published specification for this PDU, covering compliance, form factor, load capacity (VA) and input voltage. If you need a figure that is not listed, ask and we will source it.
Where the CyberPower PR2000RTXL2UTAA is deployed
- Swapping out a failed PDU for PR2000RTXL2UTAA under change control
- Adding metered or switched power to an existing cabinet
- Sizing runtime for a scheduled maintenance window
Who this part is for
- Data centre teams matching outlet type and phase to a rack build
- Teams replacing batteries or a UPS at end of service life
- Procurement buying power hardware ahead of a scheduled install
What you get ordering this from us
Ordered by part number
Quoted and supplied against PR2000RTXL2UTAA specifically, so what arrives is what your build sheet asks for.
No substitutions without asking
If we cannot supply the exact code we tell you what we can supply and why, rather than shipping an equivalent and letting you find out.
Compatibility checked
We confirm the part is supported on your platform before it ships, rather than leaving the check to you.
Questions buyers ask about this part
Is PR2000RTXL2UTAA genuine and is the warranty intact?
Yes. It ships new in CyberPower packaging, which is what keeps the warranty and the firmware entitlement valid. Anything we cannot supply that way we tell you about before you order.
Will PR2000RTXL2UTAA work in my server?
Tell us the circuit feeding the rack, the plug types in it and the measured load. Outlet count is the last thing that matters; phase, connector and real draw are the first three.
What load is PR2000RTXL2UTAA rated for?
CyberPower rates PR2000RTXL2UTAA at 2000 VA, with sine wave output, with a run time of 4.30 minutes at full load. Size it against the measured draw of what it protects, not the nameplate total.
What form factor is PR2000RTXL2UTAA?
PR2000RTXL2UTAA uses the Rack/Tower form factor and takes 2U of rack space.
What should I check before ordering PR2000RTXL2UTAA?
Check that 2000 VA covers your measured load with headroom, that the supply is 120 V AC and that your outlet takes a NEMA 5-20P plug. Send us the model it is going into and we will confirm all three before CyberPower PR2000RTXL2UTAA ships.
Do you accept purchase orders and quote at volume?
Yes. We quote against a purchase order and hold the price for the quote period, with tiered rates at quantity. Net terms are available once the account is approved.
Compare other Power Distribution & UPS we stock
| Model | Brand | Key spec | Availability | From |
|---|---|---|---|---|
| APC AP7921B Switched Rack PDU 8-Outlet 1U | APC | Capacity: 3.7kW | In Stock | $805 |
| Vertiv Geist GU10012L Metered 0U 24-Outlet | Vertiv | Capacity: 7.4kW | In Stock | $1,405 |
| Tripp Lite PDUMH15 Metered 1U 8-Outlet | Tripp Lite | Capacity: 1.4kW | In Stock | $310 |
| Eaton 5PX 1500VA 2U Rack/Tower | Eaton | Capacity: 1350W / 1500VA | In Stock | $1,065 |
| Nexus Compute C13 to C14 Power Cable 0.5m | Nexus Compute | Capacity: 10A 250V | In Stock | $5 |
| Dell Power Distribution Board Cable | Dell | N/A | In Stock | Request quote |
Browse all Power Distribution & UPS or everything we stock from CyberPower.
Specifying a system, not just the part?
Most parts we ship go into a system we also build and support.