PR1000LCDRTXL2UA: CyberPower Smart App Sinewave 1000VA Rack-mountable UPS
MPN: PR1000LCDRTXL2UA|By: CyberPower

Starting from
$425
Indicative. Final pricing is confirmed with your quote.
In Stockships worldwide
Key specs
- Input Voltage
- 120 V AC
- Mounting
- Rack-mountable
- Product Model
- PR1000LCDRTXL2Ua
- Load Capacity (VA)
- 1000 VA
- Load Capacity (W)
- 750 W
- Condition:
- New (authorized channel)
- Warranty:
- Manufacturer warranty, confirmed on your quote
Prefer your own inbox? Email us about this part
Bulk order? Request volume pricing
Authorized & warrantied
Sourced through authorized distribution, with the manufacturer warranty confirmed on your quote.
Compatibility checked
Validated against your server platform before dispatch.
Delivery & lead time
Confirmed with your quote, including expedited freight where available.
Business & public sector
POs, net terms and volume pricing for qualified organizations, government and edu.
Product overview
CyberPower lists PR1000LCDRTXL2UA as a smart app sinewave 1000VA rack-mountable UPS. Runtime is a function of load, and a UPS sized on nameplate wattage rather than measured draw will not hold the rack for as long as the datasheet suggests. Tell us the measured load and we will work the runtime out properly.
PR1000LCDRTXL2UA is specified with a 1000 VA load rating, a 120 V AC input, 17 minutes of run time at full load and a rack height of 2U, as published by CyberPower.
Quote requests are answered within 48 business hours, with availability confirmed before you raise a purchase order rather than after.
Specifications
General
- Manufacturer part number
- PR1000LCDRTXL2UA
- Product Line
- Smart App Sinewave
- Product Type
- Power Distribution & UPS
- Manufacturer
- CyberPower
Technical specifications
- Product Model
- PR1000LCDRTXL2Ua
- Load Capacity (VA)
- 1000 VA
- Load Capacity (W)
- 750 W
- Input Voltage
- 120 V AC
- Run Time (Full Load)
- 17 Minute
- Run Time (Half Load)
- 40 Minute
- Waveform Type
- Sine Wave
- Receptacle Type
- NEMA 5-15R
- Receptacle Detail
- 8 x NEMA 5-15R
- Number of Battery & Surge Outlets
- 8
- Number of Surge-only Outlets
- 0
- Number of Critical Load Outlets
- 4
- Dataline Protection
- RJ-11; RG-6; RJ-45
- Transfer Time
- 4 ms
Interfaces & connectivity
- Plug/Connector Type
- NEMA 5-15P
Physical
- Mounting
- Rack-mountable
- Rack Height
- 2U
Everything below comes from CyberPower's published specification for this PDU, covering mounting, load capacity (VA), load capacity (W) and input voltage. If you need a figure that is not listed, ask and we will source it.
Where the CyberPower PR1000LCDRTXL2UA is deployed
- Sourcing PR1000LCDRTXL2UA against a build sheet that names it explicitly
- Replacing batteries or a UPS at end of service life
- Sizing runtime for a scheduled maintenance window
Who this part is for
- Teams replacing batteries or a UPS at end of service life
- Data centre teams matching outlet type and phase to a rack build
- Facilities and IT sizing runtime against measured rather than nameplate load
What you get ordering this from us
Ordered by part number
The order is placed against PR1000LCDRTXL2UA, not against a description of it, so there is no room for a substitution you did not agree to.
Compatibility checked
We confirm the part is supported on your platform before it ships, rather than leaving the check to you.
Sized on measured load
Runtime is calculated from what the rack actually draws rather than from nameplate wattage.
Questions buyers ask about this part
Is PR1000LCDRTXL2UA genuine and is the warranty intact?
Yes. It ships new in CyberPower packaging, which is what keeps the warranty and the firmware entitlement valid. Anything we cannot supply that way we tell you about before you order.
Will PR1000LCDRTXL2UA work in my server?
Tell us the circuit feeding the rack, the plug types in it and the measured load. Outlet count is the last thing that matters; phase, connector and real draw are the first three.
What is the power rating of PR1000LCDRTXL2UA?
CyberPower rates PR1000LCDRTXL2UA at 1000 VA / 750 W, with sine wave output, with a run time of 17 minutes at full load. Size it against the measured draw of what it protects, not the nameplate total.
What form factor is PR1000LCDRTXL2UA?
PR1000LCDRTXL2UA is rack mounted, takes 2U of rack space.
What should I check before ordering PR1000LCDRTXL2UA?
Check that 1000 VA covers your measured load with headroom, that the supply is 120 V AC and that your outlet takes a NEMA 5-15P plug. Send us the model it is going into and we will confirm all three before CyberPower PR1000LCDRTXL2UA ships.
Do you accept purchase orders and quote at volume?
Yes. We quote against a purchase order and hold the price for the quote period, with tiered rates at quantity. Net terms are available once the account is approved.
Compare other Power Distribution & UPS we stock
| Model | Brand | Key spec | Availability | From |
|---|---|---|---|---|
| APC AP7921B Switched Rack PDU 8-Outlet 1U | APC | Capacity: 3.7kW | In Stock | $805 |
| Vertiv Geist GU10012L Metered 0U 24-Outlet | Vertiv | Capacity: 7.4kW | In Stock | $1,405 |
| Tripp Lite PDUMH15 Metered 1U 8-Outlet | Tripp Lite | Capacity: 1.4kW | In Stock | $310 |
| Eaton 5PX 1500VA 2U Rack/Tower | Eaton | Capacity: 1350W / 1500VA | In Stock | $1,065 |
| Nexus Compute C13 to C14 Power Cable 0.5m | Nexus Compute | Capacity: 10A 250V | In Stock | $5 |
| Dell Power Distribution Board Cable | Dell | N/A | In Stock | Request quote |
Browse all Power Distribution & UPS or everything we stock from CyberPower.
Specifying a system, not just the part?
Most parts we ship go into a system we also build and support.