PDU3EVN10L2130: Tripp Lite by Eaton 8.6kW 208/120V 3PH Monitored PDU - LX Interface, Gigabit, 45 Outlets, L21-30P Input, LCD, 3 m Cord, 0U 1.8 m Height, TAA
MPN: PDU3EVN10L2130|By: Tripp Lite

Price
Quoted on request
Current pricing within 48 business hours.
In Stockships worldwide
Key specs
- Power Capacity
- 8.6kW
- Input Voltage
- 230 V AC
- Compliance
- TAA
- Transceiver Type
- LX
- Product Model
- PDU3EVN10L2130
- Condition:
- New (authorized channel)
- Warranty:
- Manufacturer warranty, confirmed on your quote
Prefer your own inbox? Email us about this part
Bulk order? Request volume pricing
Authorized & warrantied
Sourced through authorized distribution, with the manufacturer warranty confirmed on your quote.
Compatibility checked
Validated against your server platform before dispatch.
Delivery & lead time
Confirmed with your quote, including expedited freight where available.
Business & public sector
POs, net terms and volume pricing for qualified organizations, government and edu.
Product overview
Tripp Lite lists PDU3EVN10L2130 as a by eaton 8.6kW 208/120V 3PH monitored PDU. Runtime is a function of load, and a UPS sized on nameplate wattage rather than measured draw will not hold the rack for as long as the datasheet suggests. This unit is 8.6kW. Tell us the measured load and we will work the runtime out properly.
PDU3EVN10L2130 is specified with a 230 V AC input and a rack height of 0U, as published by Tripp Lite.
We return an itemised quote within 48 business hours, and we say plainly when a part is constrained rather than quoting a date we cannot hold.
Specifications
General
- Manufacturer part number
- PDU3EVN10L2130
- Product Type
- Power Distribution & UPS
- Manufacturer
- Tripp Lite
Technical specifications
- Transceiver Type
- LX
- Power Capacity
- 8.6kW
- Input Voltage
- 230 V AC
- Product Model
- PDU3EVN10L2130
- Output Voltage
- 120 V AC; 208 V AC
- TAA Compliant
- Yes
- PDU Type
- Monitored
- Phase
- Three Phase
- Receptacle Type
- IEC 60320 C19; IEC 60320 C13; NEMA 5-15/20R
- Receptacle Detail
- 6 x IEC 60320 C19; 36 x IEC 60320 C13; 3 x NEMA 5-15/20R
- Protection Type
- Overload Protection
- Power Rating (Watt)
- 8600 W
- Input Current
- 24 A
- Mount Type
- Rack-mountable
- Width
- 2.2"
- Also Ordered As
- PDU3EVN10L2130B
Interfaces & connectivity
- Plug/Connector Type
- NEMA L21-30P
Physical
- Rack Height
- 0U
- Mounting Orientation
- Vertical
- Height
- 70"
- Depth
- 2.5"
Compatibility & compliance
- Compliance
- TAA
Everything below comes from Tripp Lite's published specification for this PDU, covering compliance, transceiver type, power capacity and input voltage. If you need a figure that is not listed, ask and we will source it.
Where the Tripp Lite PDU3EVN10L2130 is deployed
- Sourcing PDU3EVN10L2130 against a build sheet that names it explicitly
- Replacing batteries or a UPS at end of service life
- Matching outlet type and phase to a new rack build
Who this part is for
- Teams replacing batteries or a UPS at end of service life
- Data centre teams matching outlet type and phase to a rack build
- Facilities and IT sizing runtime against measured rather than nameplate load
What you get ordering this from us
Ordered by part number
Quoted and supplied against PDU3EVN10L2130 specifically, so what arrives is what your build sheet asks for.
Answered by a human
A quote comes back with the reasoning attached, including the cases where we think you should buy something else.
Volume pricing
The listed price is per unit; tiered pricing applies at quantity and purchase orders are accepted.
Questions buyers ask about this part
Is PDU3EVN10L2130 genuine and is the warranty intact?
Yes. Supplied new and unopened, so the manufacturer warranty and firmware update path stay supported. No grey-market stock and no refurbished units sold as new.
Will PDU3EVN10L2130 work in my server?
Tell us the circuit feeding the rack, the plug types in it and the measured load. Outlet count is the last thing that matters; phase, connector and real draw are the first three.
What form factor is PDU3EVN10L2130?
PDU3EVN10L2130 is rack mounted, takes 0U of rack space.
What are the dimensions of PDU3EVN10L2130?
PDU3EVN10L2130 measures 70" high, 2.2" wide and 2.5" deep.
What should I check before ordering PDU3EVN10L2130?
Check that the supply is 230 V AC and that your outlet takes a NEMA L21-30P plug. Send us the model it is going into and we will confirm both before Tripp Lite PDU3EVN10L2130 ships.
Is PDU3EVN10L2130 the same part as PDU3EVN10L2130B?
Yes, physically. Tripp Lite lists this part under more than one order code (PDU3EVN10L2130, PDU3EVN10L2130B), covering the bare part, the option kit and the spare. Tell us the exact code on your paperwork and we will quote that one.
Do you accept purchase orders and quote at volume?
Yes, POs from qualified organisations, net terms on approval, and banded pricing once the quantity is worth banding. Send the number and we will price it properly.
Compare other Power Distribution & UPS we stock
| Model | Brand | Key spec | Availability | From |
|---|---|---|---|---|
| APC AP7921B Switched Rack PDU 8-Outlet 1U | APC | Capacity: 3.7kW | In Stock | $805 |
| Vertiv Geist GU10012L Metered 0U 24-Outlet | Vertiv | Capacity: 7.4kW | In Stock | $1,405 |
| Eaton 5PX 1500VA 2U Rack/Tower | Eaton | Capacity: 1350W / 1500VA | In Stock | $1,065 |
| Nexus Compute C13 to C14 Power Cable 0.5m | Nexus Compute | Capacity: 10A 250V | In Stock | $5 |
| Dell Power Distribution Board Cable | Dell | N/A | In Stock | Request quote |
| Vertiv (Liebert) Liebert 4500W (5kVA) 120/208V Hot-Swap Power Module for Liebert APS AS5/AS6 UPS Systems | Vertiv (Liebert) | Power Rating: 4500W | In Stock | $4,585 |
Browse all Power Distribution & UPS or everything we stock from Tripp Lite.
Specifying a system, not just the part?
Most parts we ship go into a system we also build and support.