PDU15NETLX: Tripp Lite by PDU 1.4kW 120V Single-Phase Switched Mini PDU - LX Platform Interface NEMA 5-15P 6 ft. (1.83 m) Cord 0U TAA
MPN: PDU15NETLX|By: Tripp Lite

Starting from
$240
Indicative. Final pricing is confirmed with your quote.
In Stockships worldwide
Key specs
- Power Capacity
- 1.4kW
- Input Voltage
- 120 V AC
- Compliance
- TAA
- Transceiver Type
- LX
- Product Model
- PDU15NETLX
- Condition:
- New (authorized channel)
- Warranty:
- Manufacturer warranty, confirmed on your quote
Prefer your own inbox? Email us about this part
Bulk order? Request volume pricing
Authorized & warrantied
Sourced through authorized distribution, with the manufacturer warranty confirmed on your quote.
Compatibility checked
Validated against your server platform before dispatch.
Delivery & lead time
Confirmed with your quote, including expedited freight where available.
Business & public sector
POs, net terms and volume pricing for qualified organizations, government and edu.
Product overview
This is the Tripp Lite by PDU 1.4kW 120V single-phase switched mini PDU, order code PDU15NETLX. Runtime is a function of load, and a UPS sized on nameplate wattage rather than measured draw will not hold the rack for as long as the datasheet suggests. This unit is 1.4kW. Tell us the measured load and we will work the runtime out properly.
PDU15NETLX is specified with a 120 V AC input and a rack height of 0U, as published by Tripp Lite.
Priced per unit, with tiered pricing at quantity. Send the number you need and we will come back with the banded price.
Specifications
General
- Manufacturer part number
- PDU15NETLX
- Product Type
- Power Distribution & UPS
- Manufacturer
- Tripp Lite
Technical specifications
- Transceiver Type
- LX
- Power Capacity
- 1.4kW
- Input Voltage
- 120 V AC
- Product Model
- PDU15NETLX
- Output Voltage
- 100 V AC; 120 V AC; 127 V AC
- TAA Compliant
- Yes
- PDU Type
- Switched
- Phase
- Single Phase
- Receptacle Type
- NEMA 5-15R
- Receptacle Detail
- 2 x NEMA 5-15R
- Power Rating (Watt)
- 1520 W
- Input Current
- 15 A
- Mount Type
- Rack-mountable; Wall-mountable
- Placement
- Under-counter
- Width
- 7"
Interfaces & connectivity
- Plug/Connector Type
- NEMA 5-15P
Physical
- Rack Height
- 0U
- Mounting Orientation
- Vertical
- Height
- 1.7"
- Depth
- 5"
Compatibility & compliance
- Compliance
- TAA
23 specifications for PDU15NETLX, covering compliance, transceiver type, power capacity and input voltage. They are the manufacturer's figures, not ours, and we check them against your platform before anything ships.
Where the Tripp Lite PDU15NETLX is deployed
- Swapping out a failed PDU for PDU15NETLX under change control
- Replacing batteries or a UPS at end of service life
- Sizing runtime for a scheduled maintenance window
Who this part is for
- Procurement buying power hardware ahead of a scheduled install
- Data centre teams matching outlet type and phase to a rack build
- Integrators quoting PDUs, management cards and probes together
What you get ordering this from us
Ordered by part number
PDU15NETLX is what is quoted and PDU15NETLX is what ships; where an alternate code is genuinely the same part we name it rather than swap it silently.
Sized on measured load
Runtime is calculated from what the rack actually draws rather than from nameplate wattage.
Answered by a human
A quote comes back with the reasoning attached, including the cases where we think you should buy something else.
Questions buyers ask about this part
Is PDU15NETLX genuine and is the warranty intact?
Yes. It ships new in Tripp Lite packaging, which is what keeps the warranty and the firmware entitlement valid. Anything we cannot supply that way we tell you about before you order.
Will PDU15NETLX work in my server?
Tell us the circuit feeding the rack, the plug types in it and the measured load. Outlet count is the last thing that matters; phase, connector and real draw are the first three.
What form factor is PDU15NETLX?
PDU15NETLX is rack mounted, takes 0U of rack space.
What are the dimensions of PDU15NETLX?
PDU15NETLX measures 1.7" high, 7" wide and 5" deep.
What should I check before ordering PDU15NETLX?
Check that the supply is 120 V AC and that your outlet takes a NEMA 5-15P plug. Send us the model it is going into and we will confirm both before Tripp Lite PDU15NETLX ships.
Do you accept purchase orders and quote at volume?
Yes, POs from qualified organisations, net terms on approval, and banded pricing once the quantity is worth banding. Send the number and we will price it properly.
Compare other Power Distribution & UPS we stock
| Model | Brand | Key spec | Availability | From |
|---|---|---|---|---|
| APC AP7921B Switched Rack PDU 8-Outlet 1U | APC | Capacity: 3.7kW | In Stock | $805 |
| Vertiv Geist GU10012L Metered 0U 24-Outlet | Vertiv | Capacity: 7.4kW | In Stock | $1,405 |
| Eaton 5PX 1500VA 2U Rack/Tower | Eaton | Capacity: 1350W / 1500VA | In Stock | $1,065 |
| Nexus Compute C13 to C14 Power Cable 0.5m | Nexus Compute | Capacity: 10A 250V | In Stock | $5 |
| Dell Power Distribution Board Cable | Dell | N/A | In Stock | Request quote |
| Vertiv (Liebert) Liebert 4500W (5kVA) 120/208V Hot-Swap Power Module for Liebert APS AS5/AS6 UPS Systems | Vertiv (Liebert) | Power Rating: 4500W | In Stock | $4,585 |
Browse all Power Distribution & UPS or everything we stock from Tripp Lite.
Specifying a system, not just the part?
Most parts we ship go into a system we also build and support.
