PC2715: Eaton Basic rack PDU, 2U, (2) L6-30P input, 4.99 kW max, 208-240V, 24A, 0 ft cord, Single-phase, TAA compliant, Outlets: (2) L6-30R
MPN: PC2715|By: Eaton

Starting from
$2,585
Indicative. Final pricing is confirmed with your quote.
In Stockships worldwide
Key specs
- Power Capacity
- 99 kW
- Input Voltage
- 230 V AC
- Compliance
- TAA
- Current Rating
- 24A
- Output Voltage
- 240 V AC
- Condition:
- New (authorized channel)
- Warranty:
- Manufacturer warranty, confirmed on your quote
Prefer your own inbox? Email us about this part
Bulk order? Request volume pricing
Authorized & warrantied
Sourced through authorized distribution, with the manufacturer warranty confirmed on your quote.
Compatibility checked
Validated against your server platform before dispatch.
Delivery & lead time
Confirmed with your quote, including expedited freight where available.
Business & public sector
POs, net terms and volume pricing for qualified organizations, government and edu.
Product overview
Part number PC2715 identifies this Eaton basic rack PDU, 2U, (2) L6-30P input, 4.99 kW max, 208-240V, 24A, 0 ft cord, single-phase, TAA compliant, outlets: (2) L6-30R. Network management cards, environmental probes and the shutdown software are usually what make a UPS useful, and they are ordered separately. This unit is 230 V AC. Tell us the monitoring you need and we will quote it as one bill of materials.
PC2715 is specified with a 230 V AC input and a rack height of 2U, as published by Eaton.
If the part is wrong for your platform we will say so and suggest the one that is, which is cheaper for both of us than a return.
Specifications
General
- Manufacturer part number
- PC2715
- Product Line
- ePDU
- Product Type
- Power Distribution & UPS
- Manufacturer
- Eaton
Technical specifications
- Power Capacity
- 99 kW
- Input Voltage
- 230 V AC
- Current Rating
- 24A
- Output Voltage
- 240 V AC
- PDU Type
- Basic
- Receptacle Type
- NEMA L6-30R
- Receptacle Detail
- 2 x NEMA L6-30R
- Protection Type
- Surge Protection; Spike Protection; EMI Filter; RFI Filter
- Power Rating (Watt)
- 4990 W
- Mount Type
- Rack-mountable
- Number of Cord/Cable
- 2
- Width
- 19"
Interfaces & connectivity
- Plug/Connector Type
- NEMA L6-30P
- Plug/Connector Detail
- 2 x NEMA L6-30P
Physical
- Rack Height
- 2U
- Mounting Orientation
- Horizontal
- Height
- 3.4"
- Depth
- 8"
Compatibility & compliance
- Compliance
- TAA
Everything below comes from Eaton's published specification for this PDU, covering compliance, power capacity, input voltage and current rating. If you need a figure that is not listed, ask and we will source it.
Where the Eaton PC2715 is deployed
- Swapping out a failed PDU for PC2715 under change control
- Replacing batteries or a UPS at end of service life
- Matching outlet type and phase to a new rack build
Who this part is for
- Facilities and IT sizing runtime against measured rather than nameplate load
- Data centre teams matching outlet type and phase to a rack build
- Integrators quoting PDUs, management cards and probes together
What you get ordering this from us
Ordered by part number
PC2715 is what is quoted and PC2715 is what ships; where an alternate code is genuinely the same part we name it rather than swap it silently.
Compatibility checked
We confirm the part is supported on your platform before it ships, rather than leaving the check to you.
Answered by a human
A quote comes back with the reasoning attached, including the cases where we think you should buy something else.
Questions buyers ask about this part
Is PC2715 genuine and is the warranty intact?
Yes, new and sealed, with the Eaton warranty and the firmware update path intact. We do not sell refurbished stock as new, and we do not source grey-market units.
Will PC2715 work in my server?
Tell us the circuit feeding the rack, the plug types in it and the measured load. Outlet count is the last thing that matters; phase, connector and real draw are the first three.
What form factor is PC2715?
PC2715 is rack mounted, takes 2U of rack space.
What are the dimensions of PC2715?
PC2715 measures 3.4" high, 19" wide and 8" deep.
What should I check before ordering PC2715?
Check that the supply is 230 V AC and that your outlet takes a NEMA L6-30P plug. Send us the model it is going into and we will confirm both before Eaton PC2715 ships.
Do you accept purchase orders and quote at volume?
Yes. Purchase orders are accepted from qualified organisations, net terms are available on approval, and tiered pricing applies at quantity. Tell us how many you need.
Compare other Power Distribution & UPS we stock
| Model | Brand | Key spec | Availability | From |
|---|---|---|---|---|
| APC AP7921B Switched Rack PDU 8-Outlet 1U | APC | Capacity: 3.7kW | In Stock | $805 |
| Vertiv Geist GU10012L Metered 0U 24-Outlet | Vertiv | Capacity: 7.4kW | In Stock | $1,405 |
| Tripp Lite PDUMH15 Metered 1U 8-Outlet | Tripp Lite | Capacity: 1.4kW | In Stock | $310 |
| Nexus Compute C13 to C14 Power Cable 0.5m | Nexus Compute | Capacity: 10A 250V | In Stock | $5 |
| Dell Power Distribution Board Cable | Dell | N/A | In Stock | Request quote |
| Vertiv (Liebert) Liebert 4500W (5kVA) 120/208V Hot-Swap Power Module for Liebert APS AS5/AS6 UPS Systems | Vertiv (Liebert) | Power Rating: 4500W | In Stock | $4,585 |
Browse all Power Distribution & UPS or everything we stock from Eaton.
Specifying a system, not just the part?
Most parts we ship go into a system we also build and support.