OL10KRTMB: CyberPower Smart App Online UPS Systems
MPN: OL10KRTMB|By: CyberPower

Starting from
$5,100
Indicative. Final pricing is confirmed with your quote.
In Stockships worldwide
Key specs
- UPS Topology
- Online
- Input Voltage
- 230 V AC
- Product Model
- OL10KRTMB
- Form Factor
- Rack/Tower
- Load Capacity (VA)
- 10000 VA
- Condition:
- New (authorized channel)
- Warranty:
- Manufacturer warranty, confirmed on your quote
Prefer your own inbox? Email us about this part
Bulk order? Request volume pricing
Authorized & warrantied
Sourced through authorized distribution, with the manufacturer warranty confirmed on your quote.
Compatibility checked
Validated against your server platform before dispatch.
Delivery & lead time
Confirmed with your quote, including expedited freight where available.
Business & public sector
POs, net terms and volume pricing for qualified organizations, government and edu.
Product overview
This is the CyberPower smart app online UPS systems, order code OL10KRTMB. Runtime is a function of load, and a UPS sized on nameplate wattage rather than measured draw will not hold the rack for as long as the datasheet suggests. Tell us the measured load and we will work the runtime out properly.
OL10KRTMB is specified with Online topology, a Rack/Tower form factor, a 10000 VA load rating, a 230 V AC input and 3.60 minutes of run time at full load, as published by CyberPower.
Priced per unit, with tiered pricing at quantity. Send the number you need and we will come back with the banded price.
Specifications
General
- Manufacturer part number
- OL10KRTMB
- Product Type
- Power Distribution & UPS
- Manufacturer
- CyberPower
Technical specifications
- UPS Topology
- Online
- Product Model
- OL10KRTMB
- Load Capacity (VA)
- 10000 VA
- Input Voltage
- 230 V AC
- Output Voltage
- 200 V AC; 208 V AC; 220 V AC; 230 V AC; 240 V AC
- Run Time (Full Load)
- 3.60 Minute
- Run Time (Half Load)
- 10 Minute
- Waveform Type
- Sine Wave
- Receptacle Type
- NEMA L6-20R; NEMA L6-30R; Terminal Block
- Receptacle Detail
- 2 x NEMA L6-20R; 4 x NEMA L6-30R; 1 x Terminal Block
- Transfer Time
- 0 ns
- Dataline Protection
- RJ-11; RJ-45
- Energy Saving
- ECO Mode Efficiency >97%
- Input Voltage Range
- 200 V AC - 240 V AC
- Input Frequency
- 70 Hz
- Output Frequency
- 50.25 Hz
Interfaces & connectivity
- Plug/Connector Type
- Hardwired
Physical
- Form Factor
- Rack/Tower
- Rack Height
- 6U
The table lists 21 published specifications for OL10KRTMB, including UPS topology, form factor, load capacity (VA) and input voltage. Values are as CyberPower publishes them; ask and we will send the datasheet with the quote.
Where the CyberPower OL10KRTMB is deployed
- Sourcing OL10KRTMB against a build sheet that names it explicitly
- Replacing batteries or a UPS at end of service life
- Sizing runtime for a scheduled maintenance window
Who this part is for
- Data centre teams matching outlet type and phase to a rack build
- Facilities and IT sizing runtime against measured rather than nameplate load
- Teams replacing batteries or a UPS at end of service life
What you get ordering this from us
Ordered by part number
The order is placed against OL10KRTMB, not against a description of it, so there is no room for a substitution you did not agree to.
Sized on measured load
Runtime is calculated from what the rack actually draws rather than from nameplate wattage.
No substitutions without asking
If we cannot supply the exact code we tell you what we can supply and why, rather than shipping an equivalent and letting you find out.
Questions buyers ask about this part
Is OL10KRTMB genuine and is the warranty intact?
Yes, new and sealed, with the CyberPower warranty and the firmware update path intact. We do not sell refurbished stock as new, and we do not source grey-market units.
Will OL10KRTMB work in my server?
Tell us the circuit feeding the rack, the plug types in it and the measured load. Outlet count is the last thing that matters; phase, connector and real draw are the first three.
What is the power rating of OL10KRTMB?
CyberPower rates OL10KRTMB at 10000 VA, with sine wave output, with a run time of 3.60 minutes at full load. Size it against the measured draw of what it protects, not the nameplate total.
What form factor is OL10KRTMB?
OL10KRTMB uses the Rack/Tower form factor and takes 6U of rack space.
What should I check before ordering OL10KRTMB?
Check that 10000 VA covers your measured load with headroom, that the supply is 230 V AC and that your outlet takes a Hardwired plug. Send us the model it is going into and we will confirm all three before CyberPower OL10KRTMB ships.
Do you accept purchase orders and quote at volume?
Yes. Purchase orders are accepted from qualified organisations, net terms are available on approval, and tiered pricing applies at quantity. Tell us how many you need.
Compare other Power Distribution & UPS we stock
| Model | Brand | Key spec | Availability | From |
|---|---|---|---|---|
| APC AP7921B Switched Rack PDU 8-Outlet 1U | APC | Capacity: 3.7kW | In Stock | $805 |
| Vertiv Geist GU10012L Metered 0U 24-Outlet | Vertiv | Capacity: 7.4kW | In Stock | $1,405 |
| Tripp Lite PDUMH15 Metered 1U 8-Outlet | Tripp Lite | Capacity: 1.4kW | In Stock | $310 |
| Eaton 5PX 1500VA 2U Rack/Tower | Eaton | Capacity: 1350W / 1500VA | In Stock | $1,065 |
| Nexus Compute C13 to C14 Power Cable 0.5m | Nexus Compute | Capacity: 10A 250V | In Stock | $5 |
| Dell Power Distribution Board Cable | Dell | N/A | In Stock | Request quote |
Browse all Power Distribution & UPS or everything we stock from CyberPower.
Specifying a system, not just the part?
Most parts we ship go into a system we also build and support.
