Skip to content

300,000+ products listed onlineAI infrastructure + enterprise IT hardware. Genuine product, manufacturer warranty confirmed on your quote.

EBA302-10: Eaton ePDU G3 Basic 38U-A; 5.76 kW; In: L21-20P 16A 3P Out: 30x C13, 6x C19

MPN: EBA302-10|By: Eaton

Eaton ePDU G3 Basic 38U-A; 5.76 kW; In: L21-20P 16A 3P Out: 30x C13, 6x C19 (EBA302-10)

Price

Quoted on request

Current pricing within 48 business hours.

In Stockships worldwide

Key specs

Power Capacity
76 kW
Input Voltage
120 V AC; 230 V AC
Generation
G3
Current Rating
16A
Outlet Configuration
30x C13
All specifications
Condition:
New (authorized channel)
Warranty:
Manufacturer warranty, confirmed on your quote

Get pricing and availability

Email + WhatsApp so we always reach you.

How soon do you want to buy?

Prefer your own inbox? Email us about this part

Have questions?

Talk to a hardware specialist.

WhatsAppEmail

Bulk order? Request volume pricing

  • Authorized & warrantied

    Sourced through authorized distribution, with the manufacturer warranty confirmed on your quote.

  • Compatibility checked

    Validated against your server platform before dispatch.

  • Delivery & lead time

    Confirmed with your quote, including expedited freight where available.

  • Business & public sector

    POs, net terms and volume pricing for qualified organizations, government and edu.

Product overview

The Eaton ePDU G3 basic 38U-A; 5.76 kW; in: L21-20P 16A 3P out: 30x C13, 6x C19 is supplied under part number EBA302-10. A PDU is chosen on outlet type, phase and the circuit feeding the rack, not on outlet count. This unit presents 30x C13 outlets. Tell us the supply and the plug types in the rack and we will confirm the model.

Eaton publishes EBA302-10 with a 120 V AC; 230 V AC input, a rack height of 38U and a 10 ft cord.

Tell us the measured rack load and we will size the runtime honestly, including the batteries you will need in three years.

Specifications

General

Manufacturer part number
EBA302-10
Generation
G3
Product Line
ePDU
Product Type
Power Distribution & UPS
Manufacturer
Eaton

Technical specifications

Power Capacity
76 kW
Current Rating
16A
Outlet Configuration
30x C13
Input Voltage
120 V AC; 230 V AC
Receptacle Type
IEC 60320 C13; IEC 60320 C19
Receptacle Detail
30 x IEC 60320 C13; 6 x IEC 60320 C19
Input Voltage Range
120 V AC - 208 V AC
Power Rating (Watt)
5760 W
Mount Type
Rack-mountable
Cord Length
10 ft
Certifications & Standards
UL Listed ITE 60950-1
Width
2.1"
Manufacturer Warranty
3 Year

Interfaces & connectivity

Plug/Connector Type
NEMA L21-20P

Physical

Rack Height
38U
Height
66.5"
Weight
17 lb

Everything below comes from Eaton's published specification for this PDU, covering generation, power capacity, current rating and outlet configuration. If you need a figure that is not listed, ask and we will source it.

Where the Eaton EBA302-10 is deployed

  • Swapping out a failed PDU for EBA302-10 under change control
  • Matching outlet type and phase to a new rack build
  • Sizing runtime for a scheduled maintenance window

Who this part is for

  • Data centre teams matching outlet type and phase to a rack build
  • Procurement buying power hardware ahead of a scheduled install
  • Teams replacing batteries or a UPS at end of service life

What you get ordering this from us

Ordered by part number

EBA302-10 is what is quoted and EBA302-10 is what ships; where an alternate code is genuinely the same part we name it rather than swap it silently.

Volume pricing

The listed price is per unit; tiered pricing applies at quantity and purchase orders are accepted.

Sized on measured load

Runtime is calculated from what the rack actually draws rather than from nameplate wattage.

Questions buyers ask about this part

Is EBA302-10 genuine and is the warranty intact?

Yes, new and sealed, with the Eaton warranty and the firmware update path intact. We do not sell refurbished stock as new, and we do not source grey-market units.

Will EBA302-10 work in my server?

Tell us the circuit feeding the rack, the plug types in it and the measured load. Outlet count is the last thing that matters; phase, connector and real draw are the first three.

What form factor is EBA302-10?

EBA302-10 is rack mounted, takes 38U of rack space.

What are the dimensions and weight of EBA302-10?

EBA302-10 measures 66.5" high and 2.1" wide, and weighs about 17 lb.

What warranty does EBA302-10 carry?

EBA302-10 carries the Eaton 3-year limited warranty. We supply it new and sealed, so the manufacturer warranty applies, as confirmed on your quote.

What should I check before ordering EBA302-10?

Check that the supply is 120 V AC; 230 V AC and that your outlet takes a NEMA L21-20P plug. Send us the model it is going into and we will confirm both before Eaton EBA302-10 ships.

Do you accept purchase orders and quote at volume?

Yes. Purchase orders are accepted from qualified organisations, net terms are available on approval, and tiered pricing applies at quantity. Tell us how many you need.

Compare other Power Distribution & UPS we stock

ModelBrandKey specAvailabilityFrom
APC AP7921B Switched Rack PDU 8-Outlet 1UAPCCapacity: 3.7kWIn Stock$805
Vertiv Geist GU10012L Metered 0U 24-OutletVertivCapacity: 7.4kWIn Stock$1,405
Tripp Lite PDUMH15 Metered 1U 8-OutletTripp LiteCapacity: 1.4kWIn Stock$310
Nexus Compute C13 to C14 Power Cable 0.5mNexus ComputeCapacity: 10A 250VIn Stock$5
Dell Power Distribution Board CableDellN/AIn StockRequest quote
Vertiv (Liebert) Liebert 4500W (5kVA) 120/208V Hot-Swap Power Module for Liebert APS AS5/AS6 UPS SystemsVertiv (Liebert)Power Rating: 4500WIn Stock$4,585

Browse all Power Distribution & UPS or everything we stock from Eaton.

Specifying a system, not just the part?

Most parts we ship go into a system we also build and support.