BX1350M: APC Back-UPS 1350, Compact Tower, 1350VA, 120V, AVR, LCD, 10 NEMA outlets (5 surge)
MPN: BX1350M|By: APC

Starting from
$245
Indicative. Final pricing is confirmed with your quote.
In Stockships worldwide
Key specs
- Input Voltage
- 120 V
- Form Factor
- Tower
- Load Capacity (VA)
- 1350 VA
- Load Capacity (W)
- 810 W
- Run Time (Full Load)
- 2 Minute
- Condition:
- New (authorized channel)
- Warranty:
- Manufacturer warranty, confirmed on your quote
Prefer your own inbox? Email us about this part
Bulk order? Request volume pricing
Authorized & warrantied
Sourced through authorized distribution, with the manufacturer warranty confirmed on your quote.
Compatibility checked
Validated against your server platform before dispatch.
Delivery & lead time
Confirmed with your quote, including expedited freight where available.
Business & public sector
POs, net terms and volume pricing for qualified organizations, government and edu.
Product overview
Part number BX1350M identifies this APC Back-UPS 1350, compact tower, 1350VA, 120V, AVR, LCD, 10 NEMA outlets (5 surge). Network management cards, environmental probes and the shutdown software are usually what make a UPS useful, and they are ordered separately. This unit is 120 V. Tell us the monitoring you need and we will quote it as one bill of materials.
BX1350M is specified with a 120 V input, a tower form factor, a 1350 VA load rating, 2 minutes of run time at full load and a 6 ft cord, as published by APC.
Quote requests are answered within 48 business hours, with availability confirmed before you raise a purchase order rather than after.
Specifications
General
- Manufacturer part number
- BX1350M
- Product Line
- Back-UPS Pro
- Product Type
- Power Distribution & UPS
- Manufacturer
- APC
Technical specifications
- Input Voltage
- 120 V
- Load Capacity (VA)
- 1350 VA
- Load Capacity (W)
- 810 W
- Output Voltage
- 120 V AC
- Run Time (Full Load)
- 2 Minute
- Waveform Type
- Stepped Approximated Sine Wave
- Receptacle Type
- NEMA 5-15R
- Receptacle Detail
- 5 x NEMA 5-15R; 5 x NEMA 5-15R Surge
- Number of Battery & Surge Outlets
- 10
- Cord Length
- 6 ft
- Transfer Time
- 10 ms
- Phase
- Single Phase
- Surge Energy Rating
- 789 J
- Battery Chemistry
- Lead Acid
- Typical Battery Recharge Time
- 16 Hour
Interfaces & connectivity
- Plug/Connector Type
- NEMA 5-15P
Physical
- Form Factor
- Tower
20 specifications for BX1350M, covering input voltage, form factor, load capacity (VA) and load capacity (W). They are the manufacturer's figures, not ours, and we check them against your platform before anything ships.
Where the APC BX1350M is deployed
- Like-for-like replacement of BX1350M in an existing system
- Replacing batteries or a UPS at end of service life
- Sizing runtime for a scheduled maintenance window
Who this part is for
- Facilities and IT sizing runtime against measured rather than nameplate load
- Data centre teams matching outlet type and phase to a rack build
- Integrators quoting PDUs, management cards and probes together
What you get ordering this from us
Ordered by part number
BX1350M is what is quoted and BX1350M is what ships; where an alternate code is genuinely the same part we name it rather than swap it silently.
Sized on measured load
Runtime is calculated from what the rack actually draws rather than from nameplate wattage.
Battery date checked before dispatch
Batteries are consumable; we confirm the manufacture date rather than shipping stock that has been sitting.
Questions buyers ask about this part
Is BX1350M genuine and is the warranty intact?
Yes, new and sealed, with the APC warranty and the firmware update path intact. We do not sell refurbished stock as new, and we do not source grey-market units.
Will BX1350M work in my server?
Tell us the circuit feeding the rack, the plug types in it and the measured load. Outlet count is the last thing that matters; phase, connector and real draw are the first three.
What is the power rating of BX1350M?
APC rates BX1350M at 1350 VA / 810 W, with stepped approximated sine wave output, with a run time of 2 minutes at full load. Size it against the measured draw of what it protects, not the nameplate total.
What form factor is BX1350M?
BX1350M uses the tower form factor.
What should I check before ordering BX1350M?
Check that 1350 VA covers your measured load with headroom, that the supply is 120 V and that your outlet takes a NEMA 5-15P plug. Send us the model it is going into and we will confirm all three before APC BX1350M ships.
Do you accept purchase orders and quote at volume?
Yes, POs from qualified organisations, net terms on approval, and banded pricing once the quantity is worth banding. Send the number and we will price it properly.
Compare other Power Distribution & UPS we stock
| Model | Brand | Key spec | Availability | From |
|---|---|---|---|---|
| Vertiv Geist GU10012L Metered 0U 24-Outlet | Vertiv | Capacity: 7.4kW | In Stock | $1,405 |
| Tripp Lite PDUMH15 Metered 1U 8-Outlet | Tripp Lite | Capacity: 1.4kW | In Stock | $310 |
| Eaton 5PX 1500VA 2U Rack/Tower | Eaton | Capacity: 1350W / 1500VA | In Stock | $1,065 |
| Nexus Compute C13 to C14 Power Cable 0.5m | Nexus Compute | Capacity: 10A 250V | In Stock | $5 |
| Dell Power Distribution Board Cable | Dell | N/A | In Stock | Request quote |
| Vertiv (Liebert) Liebert 4500W (5kVA) 120/208V Hot-Swap Power Module for Liebert APS AS5/AS6 UPS Systems | Vertiv (Liebert) | Power Rating: 4500W | In Stock | $4,585 |
Browse all Power Distribution & UPS or everything we stock from APC.
Specifying a system, not just the part?
Most parts we ship go into a system we also build and support.
