BK500: APC Back-UPS CS 500VA, 120V, beige, 6 NEMA outlets (3 surge)
MPN: BK500|By: APC

Starting from
$155
Indicative. Final pricing is confirmed with your quote.
In Stockships worldwide
Key specs
- Input Voltage
- 120 V
- Apparent Power
- 500VA
- Form Factor
- Tower
- Load Capacity (W)
- 300 W
- Run Time (Full Load)
- 3 Minute
- Condition:
- New (authorized channel)
- Warranty:
- Manufacturer warranty, confirmed on your quote
Prefer your own inbox? Email us about this part
Bulk order? Request volume pricing
Authorized & warrantied
Sourced through authorized distribution, with the manufacturer warranty confirmed on your quote.
Compatibility checked
Validated against your server platform before dispatch.
Delivery & lead time
Confirmed with your quote, including expedited freight where available.
Business & public sector
POs, net terms and volume pricing for qualified organizations, government and edu.
Product overview
Part number BK500 identifies this APC Back-UPS CS 500VA, 120V, beige, 6 NEMA outlets (3 surge). Runtime is a function of load, and a UPS sized on nameplate wattage rather than measured draw will not hold the rack for as long as the datasheet suggests. This unit is 500VA. Tell us the measured load and we will work the runtime out properly.
BK500 is specified with a 120 V input, a tower form factor, 3 minutes of run time at full load and a 6 ft cord, as published by APC.
Quotes are itemised down to the accessories, so nothing that is needed to make the part work is left off and discovered later.
Specifications
General
- Manufacturer part number
- BK500
- Product Line
- Back-UPS
- Product Type
- Power Distribution & UPS
- Manufacturer
- APC
Technical specifications
- Apparent Power
- 500VA
- Input Voltage
- 120 V
- Load Capacity (W)
- 300 W
- Output Voltage
- 120 V AC
- Run Time (Full Load)
- 3 Minute
- Run Time (Half Load)
- 15 Minute
- Waveform Type
- Stepped Approximated Sine Wave
- Packaged Quantity
- 1 Each
- Receptacle Detail
- 3 x NEMA 5-15R; 3 x NEMA 5-15R Surge
- Number of Battery & Surge Outlets
- 6
- Dataline Protection
- RJ-11
- Cord Length
- 6 ft
- Phase
- Single Phase
- Input Current
- 10 A
- Surge Energy Rating
- 480 J
Interfaces & connectivity
- Plug/Connector Type
- NEMA 5-15P
Physical
- Form Factor
- Tower
Everything below comes from APC's published specification for this PDU, covering apparent power, input voltage, form factor and load capacity (W). If you need a figure that is not listed, ask and we will source it.
Where the APC BK500 is deployed
- Swapping out a failed PDU for BK500 under change control
- Replacing batteries or a UPS at end of service life
- Sizing runtime for a scheduled maintenance window
Who this part is for
- Integrators quoting PDUs, management cards and probes together
- Data centre teams matching outlet type and phase to a rack build
- Procurement buying power hardware ahead of a scheduled install
What you get ordering this from us
Ordered by part number
Quoted and supplied against BK500 specifically, so what arrives is what your build sheet asks for.
Answered by a human
A quote comes back with the reasoning attached, including the cases where we think you should buy something else.
Volume pricing
The listed price is per unit; tiered pricing applies at quantity and purchase orders are accepted.
Questions buyers ask about this part
Is BK500 genuine and is the warranty intact?
Yes. Supplied new and unopened, so the manufacturer warranty and firmware update path stay supported. No grey-market stock and no refurbished units sold as new.
Will BK500 work in my server?
Tell us the circuit feeding the rack, the plug types in it and the measured load. Outlet count is the last thing that matters; phase, connector and real draw are the first three.
What is the power rating of BK500?
APC rates BK500 at 300 W, with stepped approximated sine wave output, with a run time of 3 minutes at full load. Size it against the measured draw of what it protects, not the nameplate total.
What form factor is BK500?
BK500 uses the tower form factor.
What should I check before ordering BK500?
Check that 300 W covers your measured load with headroom, that the supply is 120 V and that your outlet takes a NEMA 5-15P plug. Send us the model it is going into and we will confirm all three before APC BK500 ships.
Do you accept purchase orders and quote at volume?
Yes, POs from qualified organisations, net terms on approval, and banded pricing once the quantity is worth banding. Send the number and we will price it properly.
Compare other Power Distribution & UPS we stock
| Model | Brand | Key spec | Availability | From |
|---|---|---|---|---|
| Vertiv Geist GU10012L Metered 0U 24-Outlet | Vertiv | Capacity: 7.4kW | In Stock | $1,405 |
| Tripp Lite PDUMH15 Metered 1U 8-Outlet | Tripp Lite | Capacity: 1.4kW | In Stock | $310 |
| Eaton 5PX 1500VA 2U Rack/Tower | Eaton | Capacity: 1350W / 1500VA | In Stock | $1,065 |
| Nexus Compute C13 to C14 Power Cable 0.5m | Nexus Compute | Capacity: 10A 250V | In Stock | $5 |
| Dell Power Distribution Board Cable | Dell | N/A | In Stock | Request quote |
| Vertiv (Liebert) Liebert 4500W (5kVA) 120/208V Hot-Swap Power Module for Liebert APS AS5/AS6 UPS Systems | Vertiv (Liebert) | Power Rating: 4500W | In Stock | $4,585 |
Browse all Power Distribution & UPS or everything we stock from APC.
Specifying a system, not just the part?
Most parts we ship go into a system we also build and support.